All notes

Full Body Safety Harness & Fall Arrest Systems: Inspection & Clearance Guide

Master the ABCDs of fall protection, calculate safe fall clearance for 1.8m shock-absorbing lanyards vs SRLs, and run a pre-use safety harness inspection.

Full Body Safety Harness & Fall Arrest Systems: Inspection & Clearance Guide

Falls from height remain the #1 cause of construction fatalities worldwide. Under OSHA 1926.501, fall protection is mandatory at 1.8 m (6 ft) in construction and 1.2 m (4 ft) in general industry.

The ABCDs of a Personal Fall Arrest System (PFAS)

  • A — Anchor Point: Rated to at least 22.2 kN (5,000 lbs) per attached worker.
  • B — Body Harness: Full-body harness distributing arrest forces across thighs, pelvis, and shoulders (body belts are prohibited for fall arrest).
  • C — Connectors: Twin-leg shock-absorbing lanyard enabling 100% tie-off, or a Self-Retracting Lifeline (SRL).
  • D — Descent & Rescue Plan: Rapid rescue capability within 15 minutes to prevent suspension trauma.

Fall Clearance Calculation (1.8 m Lanyard)

  • Lanyard length: 1.8 m
  • Deceleration / shock pack deployment: 1.1 m
  • Worker height (D-ring to feet): 1.8 m
  • Safety margin: 0.9 m
  • Minimum required clearance ≈ 5.6 meters. Below 5.6 m, switch to a Self-Retracting Lifeline (SRL).